MARINE NOTIFICATION APPLIANCES
The marine notification appliances provide audible and visible notification for a wide range of environmental conditions and locations on vessels.
The BBR-52, BBR-110 and BBR-220 provide audible notification for applications with the Autroprime BS-200M Marine Fire Alarm Control Panel that require systems to have US Coast Guard, ABS and Lloyds Listings/Approvals.
The BBR-200 addressable sounder connects to and is powered by the Autroprime BS-200M Marine Fire Alarm Control Panel’s detector loop. Sound output level is 100dB(A) at 1 meter (3.37 feet), at 27 VDC. Sounders on same loop will have synchronized sound outputs. This sounder continuously monitors the loop voltage, and posts a message to the panel when the voltage is too low to give an acceptable sound output.
The BBR-110 is a combined detector base and addressable sounder. This sounder is loop powered and has 86 dB sound output level at 1 meter (3.37 feet), at 24 VDC.
The BBR-52 SmartBuzzer connectors to a detector base and is powered from the detector loop. It is activated as soon as the detector responds to an alarm signal. The average sound level is 80 dB at 1 meter (3.37 feet). To further increase audible coverage, the buzzer switches between two different sound frequencies. After 90 seconds the sounder will turn off, and remain locked in off-position until the alarm is manually reset from the system.
The MT-12/24-R and MTWP-2475W-FR provide audible and audible/visible notification for applications that required US Coast Guard Approval. These appliances support eight (8) audible signals. The MTWP-2475W-FR is rated for 180 cd at 77°F (25°C) and 75 cd at-31°F (-35°C).
Features
- BBR-100 and BBR-200 addressable sounders are powered by detection loop on Autroprime BS-200M Marine Fire Alarm Control Panel
- SelfVerify and automatic addressing supported with BBR-100 and BBR-200
- MT-12/24-R and MTWP-2475W-FR support 8 alerting sounds
- MTWP-2475W-FR is rated for 180 cd @ 77°F (25°C) and 75 cd @ -31°F (-35°C)
Technical Specifications
- Short circuit isolator in each BBR-100 and BBR-200
- Working Temperature: Varies by Appliance
- Degrees of Protection: IP20 (BBR-100) and IP44 (BBR-200)
Listing & Approvals
- United States Coast Guard
- American Bureau of Shipping (BBR-52, BBR-100, BBR-200)
- Lloyd’s Register (BBR-52, BBR-100, BBR-200)
- DNV/GL
- Bureau Veritas (BV)
- FM Approvals (FM)
- RINA (Registro Italiano navale)
- Nemko